Screwfix electric hob. Having an existing gas hob and electric oven (under counter) replaced. Screwfix electric hob

 
Having an existing gas hob and electric oven (under counter) replacedScrewfix electric hob  Our current gas oven depth is 523mm & the depth of the electric oven is 560mm

3/5. Electric and gas options make classic choices, while induction is. The old units are both wired into a CCU, hob - 6mm cable, oven 2. 4KW load, ideally I'd like to be able to have the 20Amp option to get the most out of it. 5A, then add them 10+11. The oven circuit is fused at 32A. ProDave New Member. He has backed ou and need to revert to NAPIT for advice. stateit Screwfix Select. 5 hr flex is fine if its a gas one 1. Delivery. View all: Unika Worktop Fittings. #4. Click & Collect. When I turned the power back on the induction hob was working fine, went back to try it later and now. But if i turn the isolator switch on with the hob disconnected its fine. One wire in the Left hand terminal looks a bit dodgy. #11. I have B32 and want a single oven and induction hob. Delivery 7 days a week Free next day delivery available. White PVC Sheathed Cable. 00 Save £60. Other users reply with their opinions and advice, including the difference between electric and induction hobs, the need for a spark, the size of the hole, and the kilowatt rating. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. Choose options. 5mm2 T&E from jb to double socket. Under worktop oven. Hi there. That will dictate how much power can be drawn from it and hence whether you can connect both appliances to the one circuit. We’re replacing our gas oven with an electric oven but keeping the gas hob. kitchen appliances. Unlike gas hobs, there are several types of electric hob, and choosing the right one for you can be confusing. The Scolmore one in your first link has two cable outlets. New ceramic electric hob to replace existing gas. If the hob is installed over a compact oven, there must be a. 5kw for the hob, a total of 10kW. IMHO, all gas hobs are technically identical, nearly, the money goes into pan support etc. Easy power isolation. So for a new cooker circuit, will they install a double socket under the worktop to plug in the electric oven and electric hob, then a single fused switch above worktop to control both at the top like this? If the induction hob will run on 16A single phase, the results will be disappointing. Hello, got a new induction hob to replace an old electric hob (the old style with raised heat elements that take an hour to heat up then 3 hrs to cool down) it is all plumbed in with a big red switch and theres a junction box behind the cooker for easy change over, just wanted to know is it just a case of connecting the right wires up and. Hob Type: Induction Hob. Works out when the temperature of cooking is too high and turns off the source of ignition, effectively preventing kitchen fires before they start. You could always think of another way though. 276. Black, Brown & Grey Cores. Electric screwdrivers are a key piece of kit allowing the user to screw and unscrew as required with complete ease. I'm currently changing my hob for a new one. That means the top of the pan supports not the worktop. I too am wanting to do this. #8. Currently the oven is left disconnected. Hi, we're looking to change out our gas hob for an electric model, as we've recently had a gas leak and the cost of getting the gas back in working order in the kitchen seems to be way higher than disconnecting the gas and running a new electric hob. 0800 324 7818. Neff T58FD20X0 80cm Induction Hob - Black. Any advice appreciated. Next to the sticker is a black plastic panel which covers the hole where the wire goes. " i. Timer. 27 Strands Per Core. The MK one in your second link is only for one cable going out. The existing socket is most likely on 2. I have had a new aeg gas hob fitted. Bazza Screwfix Select. But the hob draws 7. I edited my reply and agree. All on a 40amp breaker or would it be best to de-rate down to. Most do come with flex attatched normaly about 2 meters long. 0800 324 7818. I already have an electric oven and gas hob fitted. Please do not return to store. Choose options. Is is normal practise to wire both appliances into the outlet that is supplied by the 45A DP cooker switch on the wall? I appreciate your time if you can. UK call centre ready for your call 24/7. 00. Why not see if you can source an offcut of oak top and rebate the edges of it so it sits in neatly and mount the hob in that. 0800 324 7818. Screwfix customers rate this product 4. To do this drill a small hole just big enough for the flex in the back of the side panel, feed the flex through, fit a plug. €98. Buy Appliances at Screwfix. Number of Cooking Zones: 4 Zones. There needs to be a gap of at least 65cm between your hob and the cooker hood or ceiling. Worktop 20mm. Having ploughed through loads of specification on AO. 30 day money back guarantee. I am a bit confused ,your worktop from front to wall would typically be 600 mm or a bit more. 49Inc Vat. My electric Zanussi hob has recently started tripping the mains electric. Child / User Safety Control Lock. UK call centre ready for your call 24/7. HiNeff N50 T26BB59N0 Cast Iron Gas Hob - Stainless Steel. If the oven is designed to be plugged in via a 13A socket then it will be supplied with a factory fitted flex and moulded 3 pin plug. Choose from top trade brands. Bob Rathbone Screwfix Select. Discussion in 'Electricians' Talk' started by SpuddyMcFuddy, Nov 14, 2017. I lifted the old hob to see where the wire goes. Old hob specs from data sheet below. Screwfix customers rate this product 4. PayPal accepted online. Delivery Next day available. When the electricity network goes down, gas cooking still works, except the electric igniter, so you need a a lighter/matches. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. DIYDave. 9% APR representative (variable)* +1 more offers. Buy Fires, Stoves & Electric Heating at Screwfix. Add for Delivery. . Induction hob / electric oven. It appears the only the (steel) saucepans on top get heated so the only heat coming downwards would be limited to the temperature of the saucepan (around 100 degC) as there is no 2. 35Kw (30. You may be able to fit 2x 16mm end panels in the gaps if your opening is 632mm. While I was pondering my options it occurred to me that as induction hobs don't stay warm for an extended period there's perhaps the possibility to in effect fit the induction hobs 'below' the worktop say 30-40mm and have a 'slow close' hinge (s) at the rear of the workspace with a 'fold down' worktop, that closes say 3-5mm above the. The radial circuit already exists and the cable used is the correct guage for the load. 13 Inc Vat. Bob Rathbone Screwfix Select. Timer. Front-mounted touch controls. Buy online and collect in store in as little as 1 minute. You need to fuse the cooker hood, and ideally the oven down after the cooker switch. My question is. #2. Choose options. I was going to fit a dual appliance outlet, and a 13amp switch, and wanted to confirm if the 45a switch should go before or after the dual appliance outlet (see diagram). could it be wrong MCB rating, faulty MCB? any advice much appreciated cheers, SamDepends on the type of clips/clamps they send with the hob then. 1 x 59 x 52 cm (H x W x D) 4 zones. £109. All ovens are the same width so there's no issue there. The gas hob is to be removed and replaced with an electric induction hob, plus electric oven (oven rated at 16A). Nomad24 New Member. Repair Service Contact. Without me having to look for the model of my Neff (100cm) induction hob, I needed to run a 10mm cable for it to work at full capacity. The hob comes with a 13amp plug so all that is needed is for her to plug this into an adjacent wall socket. But there's not the prescribed 15mm of space between the oven and worktop - it's covered with a small wood panel that's started to fall down on one side. Once you have cut the pipe then you will need to do a. Make sure that the socket you test it on is RCD protected. 5kW for the oven and say 6. 2 x Plate Sizes. £72. 3 KW (max. I have checked the specification re your comment "must be a small hob" The Neff hobs have a power management menu. most hobs need minimum of 4mm cable and a 32 amp fuse at the consumer unit supplying only the hob. sinewave Screwfix Select. 29 Inc Vat. Assembly over oven, figure 2b. Product code: 087578. See below oven and induction hob power requirements. 49 Inc Vat. Looking at gas hobs that are 75 x 51 cm the holes required are. The feed from the switch goes by 6mm cable to a unswitched 45A cooker outlet plate in the wall hidden behind the cooker, from which another 6mm cable goes to the actual cooker. Having ploughed through loads of specification on AO. Products reviewed by the trade and home improvers. I have a 6mm cable from my cu to a cooker connecter box via a 45 dp switch which protected by 30A fuse, I want to wiring in a 5. Bosch HBS534BS0B Built-in Single Multifunction Oven - Stainless steel effect. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Crabtree Capital 20A 1-Gang DP Hob Switch White (7483J) compare. So in your case we would have 3. But the hob draws 7. Don't be tempted to use masses a small bead. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. Both are RCD protected. The 6mm cable will only feed the hob there will be another circuit for the oven. Hello, I am having a new electric single oven and induction hob delivered. What there is though is manufacturers fitting instructions, which should include the minimum distance from combustible material. Currently in Stock. 6 A) - so a worst-case total of 10. Personally don’t. Oven and hob packages. 8kw. Apple Pay accepted in store. To install the new induction hob this needs to be hardwired. With 15 temperature levels and 15 power levels, this cooktop is highly efficient, making it perfect for dorm rooms, home kitchens, backyard cooking, RVs, boats, and more. electric oven hob; Page 2 of 2 < Prev 1 2. Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm. Warranty: 2 years labour/5 years parts. 4. Pay your way. Screwfix Select. Click & Collect. A dedicated 32A cable runs from the CU to the oven. LAP 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket Black Nickel with LED with Black Inserts (96338) (22) compare. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. There is a switch on wall by oven. Having an existing gas hob and electric oven (under counter) replaced. Plug In and Go. London. PayPal accepted online. incoming valve is secure and that you have no. It's a heavy base wok so distributes heat evenly unlike a thin carbon steel wok. No one on here knows your ability, although I was an electrician I am now retired so electricial work I do is DIY, OK I have test equipment, but if we were to follow what we should do, then there. 7 kW into a single ring, where the 13A socket can only. Screwed Faceplate. Neither the hob or the oven should be more than 2 Mts from the control. Now take the first 10A and 30% of the remainder =11. 4 Kw total load induction. 5 mm flex. Child /. unphased, Feb 4, 2018. Child Safety Lock Mechanism. Screwed Faceplate. We have a set of three stainless steel pans designed for induction hobs ( ironically we'd bought these years before we went induction simply because they were nice pans at a bargain price ), traditional plain cast iron ones & some. Bush BIBGP 60cm Gas Pack & Electric Single Oven - S/Steel. Frustrated female New Member. com. dazz25 New Member. Home Forums > Screwfix Community Forum > Electricians' Talk > Help Fitting Electric Hob! Discussion in 'Electricians' Talk' started by dazz25, May 25, 2007. Screwfix Community Forum. 2) 220-240V 2 ~ H05V2V2-F 3G 2. Screwed Faceplate. When the electrician comes back will ask him to connect to consumer unit end and also for the oven. 24 Strands Per Core. I have and electric cooker hardwired into a cooker point that is within 2m of the cooker - i also want to put and electric induction hob on the other side of the kitchen, i will but putting in a separate feed does this also have to have a cooker switch and does it need to be visible? Neither a cooker nor a hob need isolation. A user asks how easy it is to change an electric hob for another one at home. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric hob. and you may find your hob requires even moreFront-mounted touch controls. 99 More info. jasondo23 New Member. Should the product require repair please contact our repair service to arrange collection and repair. 19 Inc Vat. 5 flex wil take 18amps, from the ccu you should run 6mm to a cooker connection plate then use 6mm from here to the hob, although they supply it on some and for the cooker, what size is it the max for a fcu is 3120wattsI am going to fit my Baumatic 636. Bob C New Member. 5mm or equiv cable length max 2m The hob has connectors for a cable but no supplied cable or plug The oven manual states 220-240v cable type: HO5VV-F 3X 1. Turn off the 32amp MCB to check. 6 So my cooker circuit is not adequate enough. £240 for a complete new hob - £220 for just the replacement glass top - if you don't feel competent to replicate how it was connected it's an easy. UK call centre ready for your call 24/7. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. Buy 13 A Electric Plugs at Screwfix. I'd be grateful for any help with the following. leaks. . It will need a 13A fuse, which will come with it. HannahBanana New Member. The other question i have concerns the hob. any help on this would be greatly. Flat surface is easy to clean. #2. The circuit supplying your existing oven will most likely be a standard 32A cooker circuit wired in 6mm2 T&E. Solvent-Free. Electric hobs require a flat surfaced pan to cook successfully as the pan will need to have full contact with the hob, unlike with gas hobs. 5mm2. The hob was 2 years old last week according to the paperwork, 2 year warranty I got when I bought this house. Can I wire L1 into the existing 20A feed into the existing feed that is being used, but wire the L2 into. Discussion in 'Electricians' Talk' started by mb, Jun 9, 2004. 5cm. I’m not an expert in this field but as it is would seem the back right hob ring will be very close to the gas supply pipe running down the wall. (of course, make sure your sink and hob cut outs are properly templated out! -seal the cut edges of the worktop before fitting the sink/hob. Buy online and collect in. Control Type: Touch. Need Help. about to purchase a separate electric oven and electric hob, at the moment I have a cooker point supplied with 10mm cable from consumer unit. To neatly finish off the paint job I am looking for a heat safe sealer to seal around the end of the hob / slightly underneath it where I can’t quite get the paint. 4 x Glass Plates. 9 adjustable power levels per zone. My electric Zanussi hob has recently started tripping the mains electric. In the main an electric hob needs letting into the work top, where a gas one has a recess in the design to catch spills, what you don't want is for the spill to run off the hob onto the work top making any items on the work top wet, my induction hob is around a 1/16 of an inch lower than work top. Please do not return to store. )I'm looking to replace my electric hob and have seen one which I like which is the correct size to fit into my work top with the above power rating. Next. PAGE 1 OF 3. 3/5. One other thing is that the hob as well as other appliances connect to a 80amp mcb as we had the kitchen redone a few years ago. Add to basket. Bob Rathbone Screwfix Select. That type of seal should not be positioned where it needs trimming. 25m Length. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm (420FH) (73) compare. 6a then 30% of fl remaining 10. Repair Service Action. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. The switch will act as an isolation switch for both. 6 x 49. Apple Pay accepted in store. Brown, Blue & Green/Yellow Cores. 2 kg. Buy a bundle. A 3kW kettle is only on for say 2 or 3 minutes at a time, whereas, a hob could be on for an hour or more at a time. #4. On this panel is a number of diagrams showing the wiring config. com. Hobs however, usualy require a dedicated 4/6mm 32A+ supply. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. The other thing that prompted us to use paper is that a couple of our favourite pans are cast iron with a base textured like a grinder wheel. 4 kw. Requires 25mm Back Box. They are: 1) 220-240V 1N ~ H05V2V2-F 3G 2. You need to seal the cut edge of the chipboard, otherwise if water gets under the hob, the chipboard will absorb it and swell up and ruin your worktop. FREE next day delivery available, free collection in 1 minute. Various styles and finishes. Electric hob question - Help : o. It's rated at 32 amp, recently got my entire fuse box re-done a few months back due to problems with it and I've no idea if this is supported. 4 x Plates. Brown, Black, Blue, Grey & Green/Yellow Cores. My first question is: is there any issue with having the hob on the same circuit as the kitchen sockets? It also says 380 to 415V between L1 and L2. Screwfix Community Forum. 5kW for the oven and say 6. High Dielectric Strength. replaced hob and still doing it. Inline Relays. 47 x 30 % =10. I want to get a new hob. Apart from this risk of the entire hob detaching and dropping into the cupboard below, (potentially tipping a pan of boiling water down your lower body causing life changing injuries) moisture could be making its way into the electrical. View all: No Nonsense Spray Paints. Discussion in 'Electricians' Talk' started by sdfuk, Sep 17, 2022. the thicker one is the hob. rogerk101 Screwfix Select. Electric Hobs 5 products Compare Sort Sort Samsung NZ64H37070K_BK 59cm Electric Hob - Black £ 383 Add to basket Smeg SI2951D_BK 90cm Electric Hob - Black £ 1,373. . Hi, i recently had gas hob/ electric oven fitted, after it was done the gas engineer said the plug socket which is above the oven needs moving. I decide to install and induction Hob and a 13 AMP electric oven, can the Induction Hob use the cooker circuit and the Oven the Kitchen? Or will I have to get a new circuit installed?. I think the hole is too big so not sure if I have to buy a large gas hob to cover space. £164. Several options available. I have looked at it and there is no give in the wire to move it out of cooker. The hob is sat right on top of the ovens and there is a small gap between the hob and the worktop at the front (see attached pics) Now its all. My old kitchen had a stand-alone cooker running off a 32amp fuse (6mm) cable but new kitchen will have separate oven and induction hob. (27) £. 98 Inc Vat. Buy online and collect in store in as little as 1 minute. Looking at the oven although its 880 height (including legs) the top is basically the controls with beding that 40mm lower. lee49 New Member. My existing one is wired into a normal 30 amp cooker switch/socket. Screwed Faceplate. The current electric hob surface dimension is 77 x 51 cm with the hole being 75. View product Smeg SI4642D_BK 60cm Electric Hob - Black £. Currently have a built in electric oven which is hard wired in to the cooker switch & socket, and a gas hob with elec spark which is plugged in to a 2 gang socket in an adjacent cupboard. Only the sealing strip can be used. Discussion in ' Electricians' Talk ' started by Monguy, Feb 3, 2022 . Discount applied in basket. Just bought a new gas hob (rated at 7. AEG HKB64450NB 60cm Gas Hob, Black. On the new Beko hob it simply states use 5x1. Page 2 of 2 < Prev 1 2. Various styles and finishes. The most practical way IMHO is to install a single socket in an adjacent base unit so you can plug in the hob ignition. You simply want to find out which fuse is on the Oven circuit and what its rating is (guessing 32A). So theres probably only about 2-4mm distance between these. Hi all. Done right it could look quite good. Free returns. However, he seems to have second throughts. oven would go on a fused spur, the hob definantly would not, the hood should be a seperate consideration (on the kitchen ring etc). I usually paint the exposed chipboard edge with waterproof PVA (several coats), but you could use yacht varnish. the issue I'm having is that I have 2 cables now ( one for oven and 1 for hob) the old cooker had 1 cable into a single connection plate. Bazza said: ↑. Sparkielev said: ↑. Mike83 Screwfix Select. Single oven yes. 7 Strands Per Core. ★★★★★ Read 9 reviews. This stainless steel hob is compact and lightweight, and has variable independent heat control and power on the two separate cooking plates: 1500W and 750W. Dr Bodgit, Oct 24, 2017. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. sparko69 Screwfix Select. 35kw. If it has a plug, add a 13A socket to the cooker circuit. Write a review. You can simply swap the existing outlet plate for the dual one and wire both appliances off it. if I get a replacement hob for my cracked glass hob do I need to be careful what side the terminals are on?Hi all, planning to replace my electric ceramic hob for an induction one. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. Buy any 10+ Save 10% - View Offer. £72. com. Order Cooke & Lewis CSB60A Built- In Single Electric Oven Stainless Steel 595mm x 595mm at Screwfix. Have a good ‘un Bazza, Oct 2, 2018 #22. 60 days free credit available. (62) From £349. ca. I have an existing 6mm cooker cable direct from the consumer unit approx 10M long currently protected by 32a mcb. You are only changing the oven, so leave hob as it is. The instruction say "Provide an Omnipolar cut off switch with a minimum contact opening of 3mm (except for plug connections if the user has access to it). Total Product Weight. As for the oven supply, if it is within 2 metres, as the crow flies, from the oven switch, and the cable and breaker are big enough, yes, the two appliances may share the same supply in a domestic installation only. FREE next day delivery available, free collection in 1 minute. Agreed UP, 10mm for a standard domestic cooker circuit is a total waste of money (and copper!) seneca, Feb 28, 2017. No Timer Function. Page 2 of 2 < Prev 1 2. Repair Service Action. That isn't the process. If a magnet will stick to your pans you'll probably be OK. View product Smeg SI4642D_BK 60cm Electric Hob - Black £.